Beyond Advanced Cardiac Life Support. Do we have to change our practice in COVID Era?

3 May

Main changes in recommendations

Personal Protective Equipment for Advanced Life Support interventions need to be at maximum level of protection of full body, eyes and airways.

CAT 3 level of protection 4 (at least) for the full body

FPP2/N95 airway filter for team members who are NOT directly involved in airway management, ventilation or manual chest compressions

FPP3/N99 airway filter for providers who are directly involved in airway management, ventilation and manual chest compressions.

Face shield and protective googles are strongly suggested

Mechanical Chest compressors devices are the gold standard to perform cardiac massage. They reduce contacts and contamination risk and team member exposure to contaminants.

Adhesive disposable pads are the only option to check rhythm and deliver shock. Dispose non-disposable, manual pads.

Passive O2 administration (via simple face mack at a rate of 15l/m) during chest compressions is the first option over bag mask ventilation when performing Basic Life Support waiting for advanced airway management.When using a Bag Valve Mask always put a HEPA/HME filter between Bag and mask to avoid contamination

Hold chest compressions when performing airway managment

Cover patient head with a transparent plastic foil to minimise virus spreading and contamination when performing airway management and bag mask ventilation

Tracheal intubation using a video laryngoscope is the first line option for advanced airway management to minimise contamination.

If video laryngoscope is not available Extraglottic devices are an acceptable first line option

Use all the implementation to improve intubation first passage success:

Video laringoscopy

Bougie

RAMP positioning

Suctioning (SALAD technique)

Use all the implementation to improve Extraglottic device placement

Laryngoscope for tongue displacement and mouth opening (DO NOT USE hands)

Deflate cuff

Lubrificate the device

Whatever plan you apply use an HEPA/HME filter immediately after the ventilation device

Use disposable cover and disposable gel to perform Ultrasound during chest compressions